Waddington Electronics Inc.

office 800-688-2645 - 417-864-3636
fax 417-864-3667

 

Pulse width to setpoint

 
 

PWALARM-1

wpe99368.gif (21444 bytes)
 

Designed for use the Waddington Ultrasonic Ranging Sensors SS 2-4 with pulse width output option.

Two independent relay output are activated based on distance pot settings and can be individual configured as top or bottom limit contacts. Optionally available with one relay output (PWALARM-1).

Available for use with S2, S3, S4.


FEATURES · Dual setpoint timer with relay outputs (PWALARM-1 or PWALARM-2) or alternately, with open collector outputs (PWALARM=OC). ·

Designed for use with Waddington ultrasonic ranging sensor systems such as Sona-Trol or PWVOLT EZ Circuit module to provide top or bottom limit signals. ·

Can be used alone if only top or bottom limit control signals are needed.

Provides limit outputs depending on the adjustable range setpoints. ·

Designed for use with SS2-4 ultrasonic ranging sensors with pulse width output option.

Requires the PWSUPPLY module to provide isolated power to the sensor head.

APPLICATIONS
 

Web brake detector

Additional independent limit outputs for existing systems.

Used to detect objects.

Example: Objects on conveyer systems.

PW ALARM 1-2-OC

Function:     PULSE WIDTH SETPOINT TIMER WITH DUAL RELAY OUTPUTS

Features:

Dual setpoint timer with relay outputs (PWALARM‑1 or PWALARM‑2) or alternately, with open collector outputs (PWALARM=OC).

Designed for use with Waddington ultrasonic ranging sensor systems such as Sona‑Trol or PWVOLT EZ Circuit module to provide top or bottom limit signals.

Can be used alone if only top or bottom limit control signals are needed.

Provides limit outputs depending on the adjustable range setpoints.

Designed for use with SS 2‑4 ultrasonic ranging sensors with pulse width output option.

Requires the PWSUPPLY module to provide isolated power to the sensor head.

 Applications:

 

Web brake detector

Additional independent limit outputs for existing systems.

Used to detect objects. Example: Conveyer systems.

     
   

·         P1 - Distance setpoint for output #1

       CCW increases setpoint distance.

·         P2-Distance setpoint for output #2

        CCW increases setpoint distance.

 

·         Header Jumper Configurations:

                                               

                             Jumpers vertical, outputs

                             Configured as bottom limits

 

 Jumpers horizontal, outputs

configured as top limits

 

 

 

 

·         J1 and J2 = output 1, term G, H, and J.